Vibration Analysis and its Influences on Performance of Centrifugal PumpVibration Analysis and its Influences on Performance of Centrifugal Pump
(IJIRST/ Volume 4 / Issue 3 / 012)(IJIRST/ Volume 4 / Issue 3 / 012)

All rights reserved byAll rights reserved by www.ijirst.orgwww.ijirst.org 6767

Fig. 3.2: FFT plot of centrifugal pump at 100% valve openingFig. 3.2: FFT plot of centrifugal pump at 100% valve opening

Maximum 10 value for above FFT are as follow:Maximum 10 value for above FFT are as follow:
100% valve open100% valve open

Sr. Sr. No No Velocity Velocity (mm/s) (mm/s) Frequency Frequency (Hz)(Hz)

1 1 30.15 30.15 19.7519.75

2 2 10.15 10.15 39.7539.75

3 3 4.92 4.92 79.579.5

4 4 2.69 2.69 59.559.5

5 5 1.75 1.75 99.2599.25

6 6 1.4 1.4 84.584.5

7 7 1.22 1.22 277.8277.8

8 8 0.89 0.89 297.8297.8

9 9 0.74 0.74 283283

10 10 0.6 0.6 164164